MIL-DTL-45334E
TABLE IV. Classification of defects.
Method of
Defect
Category
examination
Critical
None
Major:
101
Dimensions affecting interchangeability, not within
SIE 1/
tolerance (see 3.3.1).
Minor:
201
Dimensions not affecting interchangeability not within
SIE
tolerance (see 3.3).
202
Improper finish (see 3.5).
Visual
203
Improper marking (see 3.6).
Visual
1/ SIE = Standard Inspection Equipment.
4.4 Conformance inspections. Conformance inspection shall include the examinations of
4.4.2 (see table IV) and the test of 4.5.3.5, 4.5.4.1 or 4.5.5.2, as applicable (see table V).
TABLE V. Classification of inspections.
Require-
Inspec-
First
Confor-
Compressor
Title
ment
tion
article
mance
A, B, & C
Power input
3.4.1.1
4.5.3.1
X
A, B, & C
Oil flow
3.4.1.2
4.5.3.2
X
A, B, & C
Discharge air temperature 3.4.1.3
4.5.3.3
X
A
Life test
3.4.1.4
4.5.3.4
X
A
Pressure buildup time
3.4.1.5
4.5.3.5
X
B
Fungus
3.4.4.1
4.5.6.1
X
B
Power input
3.4.1.1
4.5.3.1
X
B
Oil flow
3.4.1.2
4.5.3.2
X
B
Discharge air temperature 3.4.1.3
4.5.3.3
X
B
Pressure buildup time
3.4.1.5
4.5.3.5
X
B
Vibration
3.4.4.3
4.5.6.3
X
B
Power input
3.4.1.1
4.5.3.1
X
B
Oil flow
3.4.1.2
4.5.3.2
X
B
Discharge air temperature 3.4.1.3
4.5.3.3
X
B
Pressure buildup time
3.4.1.5
4.5.3.5
X
X
C
Corrosion
3.4.4.2
4.5.6.2
X
C
Power input
3.4.1.1
4.5.3.1
X
C
Oil flow
3.4.1.2
4.5.3.2
X
C
Discharge air temperature 3.4.1.3
4.5.3.3
X
C
Pressure buildup time
3.4.1.5
4.5.3.5
X
13