MIL-DTL-45334E
3.4.4.3 Vibration resistance. Compressor, governor, and air cleaner shall operate as in
intended use after undergoing procedure specified in 4.5.6.3.
3.4.4.4 Shock resistance. Compressor, governor, and air cleaner shall operate as in
intended use after undergoing procedure specified in 4.5.6.4.
3.5 Finish. Unless otherwise specified, all interior metal surfaces, other than the shaft and
mounting flange, shall be treated and painted in accordance with the standard practice of the
manufacturer. When specified (see 6.2), the finish coat shall be forest green enamel (see 4.5.2).
3.6 Identification markings. The complete compressor and each major component shall
be marked as specified on applicable drawings (see 4.5.2). If not specified on the applicable
drawing, marking shall include:
a. Manufacturer's identification.
b. National Stock Number (NSN).
c. Part of Identifying Number (PIN).
4. VERIFICATION
4.1 Classification of inspections. The inspection requirements specified herein are
classified as follows:
a. First article inspection (see 4.3).
b. Conformance inspections (see 4.4).
4.2 Inspection conditions. Unless otherwise specified (see 6.2), all inspections shall be
conducted under the following conditions:
a. Air temperature: 77 + 10 degrees Fahrenheit (°F) (25 +5.5 degrees Celsius (°C)).
b. Barometric pressure: 28.5 (+2, - 3) in. of mercury (Hg)
(96.24 (+6.75, -10.13) kPa).
c. Relative humidity: 50 + 30 percent.
4.3 First article inspection. First article inspection shall be preformed on three
compressors of each type or three compressor accessories when a first article is required.
Inspection shall consist of examination for the defects specified in table IV and testing as specified
in table V.
4.3.1 Examination. Each sample selected in accordance with 4.4.1.2 shall be examined
and shall be free from any defects as listed in table IV.
12
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business