MIL-PRF-62364B
h. Fungus growth. Environmental conditions conducive to fungus growth shall not
impair brake performance or operation.
3.6 Identification marking. Unless otherwise specified (see 6.2), marking shall be
permanent and legible and shall include, as a minimum, the manufacturer's identification code
(CAGE), the contract number, and the national stock number (NSN) (see 4.5.2).
4. VERIFICATION
4.1 Classification of inspections. The inspection requirements specified herein are
classified as follows:
a. First article inspection (see 4.3).
b. Conformance inspection (see 4.4).
4.2 Inspection conditions. Unless otherwise specified (see 6.2), all inspections shall be
conducted under the following conditions:
a. Air temperature: 77 + 10°F.
b. Barometric pressure: 28.5 (+2, - 3) inches Hg of mercury.
c. Relative humidity: 50 + 30 percent.
4.3 First article inspection. Unless otherwise specified (see 6.2), first article inspection
shall be performed on preproduction or initial production samples as specified when a first article
sample is required (see 3.1). This inspection shall include the examinations of 4.5.2 (see table II)
and the tests of 4.5.3 through 4.5.3.10 (see table III).
TABLE II. Classification of defects.
Method of
examination
Category
Defect
Major:
101
Incomplete assembly (see 3.3)
Visual
102
Incorrect dimensions affecting interchangeability (see 3.3). SIE 1/
103
Improper routing of safety wire (see 3.3).
Visual
Minor:
201
Incorrect dimensions not affecting interchangeability
SIE
(see 3.3).
202
Improper identification marking (see 3.6).
Visual
1/ SIE = Standard Inspection Equipment.